<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Heat and Mass Transfer Research</JournalTitle>
				<Issn>2345-508X</Issn>
				<Volume>6</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>05</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Rapid Mixing of Newtonian and Non-Newtonian Fluids in a Three-Dimensional Micro-Mixer using Non-Uniform Magnetic Field</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>55</FirstPage>
			<LastPage>61</LastPage>
			<ELocationID EIdType="pii">3504</ELocationID>
			
<ELocationID EIdType="doi">10.22075/jhmtr.2018.15611.1218</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Morteza</FirstName>
					<LastName>Bayareh</LastName>
<Affiliation>Mechanical Engineering, Shahrekord University, Shahrekord, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Azam</FirstName>
					<LastName>Usefian</LastName>
<Affiliation>Department of Mechanical Eng., Shahrekord University, Shahrekord, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Afshin</FirstName>
					<LastName>Ahmadi Nadooshan</LastName>
<Affiliation>Department of Mechanical Eng., Shahrekord University, Shahrekord, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>08</Month>
					<Day>14</Day>
				</PubDate>
			</History>
		<Abstract>The mixing of Newtonian and non-Newtonian fluids in a magnetic micro-mixer was studied numerically using  ferrofluid. The mixing process was performed in a three-dimensional steady-state micro-mixer. A magnetic source was mounted at the entrance of the micro-channel to oscillate the magnetic particles. The effects of electric current, inlet velocity, size of magnetic particles, and non-Newtonian fluid were examined on the mixing efficiency. It was demonstrated that the mixing efficiency would increase with applied current and the size of magnetic particles. The inlet velocity has an inverse effect on the enhancement of the mixing efficiency. It is found that electric currents of 0A and 50A would lead to the mixing efficiency of 10% and 83%, respectively. In addition, the results of the present work revealed that the mixing efficiency of a non-Newtonian fluid (blood) is smaller than that of a Newtonian one.           </Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Micro-mixer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Magnetic field</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Mixing efficiency</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electric current</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Ferrofluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Non- Newtonian fluid</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jhmtr.semnan.ac.ir/article_3504_fb610095be65ef4e26bc76d2cc4d4156.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
