<ArticleTitle>Statistical Analysis of Nanofluid Heat Transfer in a Heat Exchanger using Taguchi Method</ArticleTitle>
<VernacularTitle>آنالیز آماری انتقال حرارت نانوسیال در یک مبدل حرارتی با استفاده از روش تاگوچی</VernacularTitle>
			<FirstPage>29</FirstPage>
			<LastPage>38</LastPage>
			<ELocationID EIdType="pii">4708</ELocationID>
			
<ELocationID EIdType="doi">10.22075/jhmtr.2020.20678.1287</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Behrouz</FirstName>
					<LastName>Raei</LastName>
<Affiliation>Department of Chemical Engineering, Mahshahr Branch, Islamic Azad University, Mahshahr, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2020</Year>
					<Month>06</Month>
					<Day>21</Day>
				</PubDate>
			</History>
		<Abstract>In this study, a statistical experimental design method (the Taguchi method with L9 orthogonal array robust design) was performed to optimize experimental conditions such that to maximize the Nusselt number of Al&lt;sub&gt;2&lt;/sub&gt;O&lt;sub&gt;3&lt;/sub&gt;-water nanofluids in a double tube counter flow heat exchanger. The controllable factors were selected at three sets of conditions including temperature (45, 55, and 65℃), concentration (0, 0.05, and 0.15 vol.%), and flow rate (7, 9, and 11 l/min) of the nanofluid. Analysis of the obtained results revealed that the flow rate plays a key role in the Nusselt number of nanofluid with 63.541%. The optimal levels were defined for the three factors including the nanofluid concentration of 0.15 vol.%, the nanofluid temperature of 65℃,and the nanofluid flow rate of 11 l/min. The predicted Nusselt number of nanofluid under these conditions was 322.633. The confirmation test was also performed at the optimal conditions, by which good consistency was found between the experimental and the predicted results.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Taguchi method</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Nanofluid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Nusselt number</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Heat exchanger</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jhmtr.semnan.ac.ir/article_4708_9293768b4b16f26820a1df5e59e0f0be.pdf</ArchiveCopySource>
</Article>
</ArticleSet>